Home > Products > Fire Alarm & Smoke Detector > CE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke Sensor
              CE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke Sensor
              • CE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke SensorCE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke Sensor
              • CE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke SensorCE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke Sensor
              • CE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke SensorCE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke Sensor
              • CE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke SensorCE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke Sensor

              CE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke Sensor

              Asenware LPCB EN54 approve conventional smoke detectorIntroduction:AW-CSD381 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.The conventio......

              Send Inquiry

              Product Description

              Asenware LPCB EN54 approve conventional smoke detector
              CE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke Sensor

              Introduction:
              AW-CSD381 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.

              The conventional rate of rise of rise heat detector uses thermal component to detect the temperature changing in the environment. It can enable fire alam when the temperature difference achieved the setting rate of rise temperature value reach the setting fixed ualue. It has a stable and reliable working performance.

              Two LEDs on each detector provide local 360° visible alarm indication. They flash every six seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.

              The detector that initiated the alarm condition will have its red LED and relays latched until reset by panel.

              Operating Voltage Range9 to 28 VDC Volts Non-polarized
              Standby Current≤120uA@24VDC
              Maximum Alarm Current (LED on)

              ≤15mA@24VDC

              (1K Ohm current-limiting resistance)

              Operating Humidity Range≤95%RH(40ºC±2ºC)RelativeHumidity,Non-condensing
              Operating Temperature Range-10ºC to 50ºC(14ºF to 122ºF)
              Smoke Alarm Sensitivity0.1-0.15dB/m
              Height48.2mm installed in Base
              Diameter99.45mm
              Standard Number refEN 54-7:2000
              EC certificate0832-CPR-F2071

              Detailed Images:
              CE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke SensorCE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke Sensor
              CE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke Sensor
              CE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke Sensor
              Packaging & Shipping

              Packaging Details:
              1) PEE bag per unit 
              2) Outside Cartons
              3)Strict & Standard Export Packing Procedures Adopted Exterior Corrugated Hardboard Carton Interior Blister Buffer Staff, Asenware fire pump control equipment.
              CE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke Sensor




              Our company
              Asenware, manufacturer of fire alarm and fire suppression system since 2005. Our headquarter is in London, UK, with factory Shenzhen, China
              We keep our best service for our customers, and have a rich experienced engineer team to design and install for overseas projects.

              Product range
              1. Addressable fire alarm system(FP100 series,2189,2100 series)
              2. Conventional fire alarm system(2166 series)
              3. FM200 gas fire suppression system
              4. Emergency light system
              5. Fire pump system
              6. Fire hose and fire hose reel cabinet

              Company Information:

              ASENWARE is the fire alarm system and fire suppression system manufacturer and whole fire safety solution provider since 2005.

              Driven by a commitment to sound operations, ongoing innovation, and open collaboration, we have established a competitive fire safety products line include addressable fire alarm system, conventional fire alarm system, central monitoring emergency light system, fire telephone and emergency audio system, fire pump, fire hose and gas suppression system.

              Our fire safety products ,solutions and services are used in over 100 countries.
              With over 200 employees work in United Kingdom-Marketing Center, China-R&D and Supply Chain Center and Bangladesh-Manufacture
              Center, ASENWARE is committed to design and manufacture the best fire safety products to reduce the risk of fire, and support theworld to be more safe and more comfortable.
              CE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke Sensor


              CE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke Sensor
              CE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke Sensor
              CE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke Sensor
              CE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke Sensor










               

              Our Services

              1.OEM / ODM services.
              2.Professional technical team.
              3.Offer Free technical support whenever you need
              4.Two year warranty and technical maintenance

              FAQ 
              CE/Lpcb Conventional Fire Alarm Smoke Detector Alarm Smoke Sensor


              Q1: Are you manufacturer?
              A: (yes)
              Q2: What is the lead time?
              A: usually
              Fire control: one week working day
              bulk quality: three weeks working days
              Emergency lights: two weeks working days
              bulk quality: four weeks
              FM200:  two weeks working day
              Fire pump: 25 days
              Q3: How do you ship the goods and how long does it take arrive?
              A: We usually ship by DHL, UPS, FedEx or by Air. 3-5 days after payment received.
              Q4: Can I have a sample order?
              A:Yes,we welcome sample order to test and check quality.
              Q5: Do you offer OEM service?
              A: Yes, we can design the things according to your request.

              Related Category

              Send Inquiry

              Please Feel free to give your inquiry in the form below. We will reply you in 24 hours.
              Click Refresh verification code

              Leave Your Message

              • Click Refresh verification code